Barra antiestática EX 1250

ex1250
ex1250
Static Eliminator Bar

The EX1250 Bar is a high performance static
eliminator with ATEX certification for use in
hazardous areas.

The EX1250 is suitable for Zone I and Zone 2
hazardous areas. Please see certification
details on page 2.


Benefits and Advantages

•       The EX1250 is part the 1250 family of static eliminators, which offer market-leading reliability and performance
•       The EX1250 has a resistively coupled design for neutralising high charges at fast speeds.
•       Maximum ionisation performance in a hazardous area.
•       Stay-sharp etched emitters for better long term performance. Life 5 years +. Non-infectious.
•       Emitters at 15mm pitch provide more ionisation and so better neutralisation.
•       Robust construction, but compact and easy to install. Swivel screw-in cable connectors.
•       Operating distance up to 150mm. Best distance for high speeds and high charges 25 - 50mm.
•       Washable and suitable for food, medical and pharmaceutical applications.
•       Optional remote function monitoring showing status of high voltage and whether Bars require cleaning.


schema1

EX1250 Static Eliminator Bar


schema3

Remote Function Monitor for Power Unit

The Remote Function Monitor measures the high voltage output and indicates if there is a fault which results in no ionisation. The fault could be:
A) in the mains supply
B) a short in the Bar or cable
C) a fault in the power unit
D) Bars require cleaning

If there is a fault in the EX1250 Bar the Power Unit will shut down for safety reasons - it is current limited to 5mA.

It also indicates if the Bars require cleaning

The electronic circuitry for the Remote Function Monitor (RFM) is on a PCB mounted inside the Power Unit. It does not need any additional power source.

The connector on the Power Unit can give a no volt signal which can go to an alarm or PLC on the machine. There is a choice of logic options available. See below.